Vacuum pump parameter explanation: quickly read the technical parameter table

Vacuum pump parameter explanation: quickly read the technical parameter table

Helium mass spectrometry leak detectors often require the use of vacuum pumps. In the purchase of vacuum pumps, manufacturers will put the technical parameter table in an important position for our reference.

A vacuum pump technical parameter table may include: pumping speed, limit vacuum, pumping volume, vitesse, starting pressure, limit pressure, need to be equipped with the front pump, maintenance pump and other information.

What exactly do these parameters mean? Today, I will provide you with the definition of the parameters to help you quickly understand the technical parameter table.

Vacuum degree: The degree of thin gas in a vacuum state, usually expressed by “high vacuum” et “low vacuum”. The units are Torr or Pa.

Pumping rate: Unit m³/h or L/S, refers to the gas pumped from the vacuum pump inlet in a unit time under a certain pressure and temperature.

The unit is m³/s or l/s, which refers to the gas flow at the pump inlet.

Vitesse: Unit r/min, the rotation speed of the rotor.

Ultimate vacuum: After the vacuum pump is fully pumped, it is stabilized at a certain vacuum degree, which is the ultimate vacuum of the pump.

Usually, the vacuum pump needs to undergo 12 hours of refining, and then vacuum for 12 heures, and the last hour is measured every 10 minutes, and the average of the 6 times is the limit vacuum value.

Ho’s coefficient: The ratio of the actual pumping speed on the suction channel area of the vacuum pump to the theoretical pumping speed calculated on the basis of molecular discharge.

Flow conductance: indicates the ability of the vacuum pipe to pass the gas. In a stable state, the flow conductance of the pipe is equal to the flow rate of the pipe divided by the pressure difference at both ends of the pipe, in L/s.

Water vapor allowance: unit kg/h, refers to the mass flow of water vapor that can be removed by the gas town pump in continuous operation under normal working environment.

Mean free path: The average distance traveled by two successive collisions of gas particles in random thermal motion, denoted by the symbol “λ”.

Standard atmospheric pressure: Pressure of 101325 dynes per square centimeter, unit Atm.

Pressure or pressure: The force exerted by a gas molecule on a unit area of a container wall, expressed in Pa.

Starting pressure: refers to the pressure when the pump starts without damage and has pumping effect.

Front pressure: refers to the outlet pressure of the vacuum pump with the exhaust pressure lower than one atmosphere.

Maximum front pressure: means that the pressure exceeds the front pressure that can cause damage to the pump.

Maximum working pressure: Only the inlet pressure corresponding to the maximum extraction volume. At this pressure, the pump can work continuously without deterioration or damage.

Main pump: In a vacuum system, a vacuum pump used to obtain the required degree of vacuum to meet specific process requirements.

Front pump: Vacuum pump used to maintain the critical front pressure of a vacuum pump in the front pressure region. Par exemple, the rotary vane pump or slide valve pump configured before the Roots pump is the front pump.

Coarse pumping pump: Vacuum pump that starts pumping gas at atmospheric pressure and pumps the system pressure to another vacuum pump to start working.

Maintenance pump: In the vacuum system, the air volume is very small, can not effectively use the previous pump. This is equipped with a small capacity of the auxiliary pump to maintain the main pump work, the pump is called maintenance pump. If the diffusion pump outlet is equipped with a small rotary vane pump, it is a maintenance pump.