Description

Cable ground fault locator

KDJK-10A single-phase grounding fault locator is suitable for single-phase grounding fault lines of overhead lines in small current distribution networks. When single-phase grounding fault occurs and the lines are shut down, the device can be accurately located at the docking point of the device.

KDJK-10A single-phase grounding fault locator is a portable device that can locate faults of multiple lines. The whole equipment consists of transmitter, capteur, receiver and accessories. After the fault line is shut down, the transmitter applies ultra-low frequency high voltage signal to the line to make the fault repeat, and the sensor is hung on the line with an insulated rod along the line to detect the signal, and the data is transmitted wirelessly to the receiver on the ground, and the receiver displays the measurement result. Before the fault point, the current continues to exist, after the fault point, the current disappears. The fault location can be quickly determined by rough segmentation followed by precise fixing.

Cable ground fault locator

Caractéristiques du produit
1. Il convient au réseau de distribution du système de mise à la terre de petit courant pour détecter la mise à la terre métallique monophasée, mise à la terre, Ressentiel de transition About et autres défauts des lignes aériennes.
2. Positionnement après la panne de ligne, Particulièrement adapté aux lignes défectueuses avec des branches de câbles (10kv, 35Lignes aériennes KV).
3. En injectant le signal de détection dans la phase de défaut de la ligne, Le point de défaut de mise à la terre monophasé est déterminé, ce qui réduit la cécité et réduit le temps de détection des défauts.
4. Dans l'état de panne de puissance de ligne, il peut localiser rapidement et avec précision le point de défaut de sol monophasé avec une erreur inférieure à 1 mètre.
5. Utilisation de la méthode dichotomique pour la détection, il n'a pas besoin d'inspection complète, et réduit le temps de détection des défauts.
6. Lorsque la ligne fonctionne normalement, le courant de charge de ligne (0-100mA) peut être détecté.
Seven. Il fonctionne sur le sol à travers une tige isolante, Et il devrait y avoir un dispositif de protection contre les fusibles à l'intérieur de l'appareil pour assurer la sécurité personnelle.
8. The device has a variety of power modules built in ultra-low frequency composite signal source, Source du signal de puissance, high voltage signal source, Et l'appareil réalise une variété de modes de travail.
9. L'appareil est équipé d'une variété de systèmes de réception, qui n'interfèrent pas les uns avec les autres, et peut être testé simultanément ou séparément.
10. Le signal haute tension est appliqué pour faire la répétition de la défaut, et le signal actuel est stable et facile à détecter.
11. Le signal de fréquence ultra-bas évite l'influence de la capacité distribuée par système et peut localiser les défauts avec des valeurs de résistance élevées.
12. Caractéristiques de sécurité de l'émetteur: Fonction de blocage de démarrage haute tension, La sortie permet un court-circuit direct.
13. Capteur avec capteur à haute sensibilité, Facile à connecter en ligne.
14. Transmission de communication sans fil du capteur et du récepteur, sûr et fiable.
Quinze. L'appareil a une variété de fonctions de protection et a de bonnes performances de test de sécurité.
16. The transmitter can use mains power, generator power supply, sensor and receiver dry battery power supply.
17. When the power supply voltage is too low, the alarm should be prompted to charge.
18. Operated by insulated rod with internal fuse protection.
19. The device has a variety of power modules built in ultra-low frequency composite signal source, Source du signal de puissance, high voltage signal source, Et l'appareil réalise une variété de modes de travail.
20. Small size and light weight of transmitter; The sensor is designed to reduce the volume and weight, and it is convenient to connect along the line. The receiver is designed for handheld.

1, Générateur de signal de test à haute tension de défaut de mise à la terre

Positioning accuracy 0.1m
Output frequency 22Hz
Open circuit voltage fundamental wave RMS 0 ~ 2800V
Pulsating DC, peak 16kV, equivalent to the peak phase voltage of a 20kV line
Short-circuit current fundamental RMS 0 ~ 35mA (pulsating DC, peak 100mA)
Plage de mesure de la défaut de terre Résistance au sol ≤ 100 kΩ
Longueur de ligne de détection ≥120 km

 

Short-circuit current fundamental wave RMS 0 ~ 30mA
Plage de sortie du signal 0 ~ 100mA
Précision de sortie du signal ± 1 mA

 

Wireless communication distance between sensor and receiver not less than 30m
Transmitter output power Maximum power 900W
Transmitter power supply AC 220V mains, generator (output power ≥1000W)
Poids 15kg
Volume 400×300×220mm

Cable ground fault locator

2, émetteur de signal de défaut de ligne aérienne

Detect the cross-frequency signal emitted by the test signal generator.
Automatic timing.
Automatically displays the communication status with the pliers meter.
Automatic display of device voltage.
Automatic low voltage alarm.
Detects the load current of the line.
Clamp CT was used to measure the different frequency signal and load current.
Can be used to measure insulated lines.
Can display the current clamp battery status and battery voltage in real time.
Précision de test ±1%±3dgt(23℃ ± 5 ℃, below 80%RH)
Portée de détection 0.1mA ~ 100.0mA
Transmission mode wireless RF mode
Transmission frequency 433MHz
Transmission distance ≥30m

 

Mouth diameter ≥40mm
Température de fonctionnement -30℃ ~ 70℃
Source de courant 3 Non. 7 alkaline dry batteries.
Poids 0.45kg
Volume 87×37×262mm

3, récepteur de signal de défaut de ligne aérienne

Receive and display data from a handheld data detector.
You can lock and hold data.
In automatic pairing, the communication status with the pliers meter is displayed automatically.
Automatic display device voltage, automatic low voltage alarm.
Display the detected signal size in digital mode.
Data transmitted by handheld signal detection devices can be stored.
Mode d'affichage: Large screen LCD, backlight function.
Distance sans fil not less than 80m
Historical data can be stored ≥500 times.
You can set up a variety of ways to work.
Data from the host and receiver can be read.
Température de fonctionnement -30℃ ~ 70℃.
Source de courant 5 Non. 5 alkaline dry batteries.
Poids 0.45kg
Volume 100×35×204mm