Description

GA-EDX-8000 ROHS1.0 X-ray Fluorescence Spectrometer

1.Instrument overview

Modèle du produit :EDX8000 ROHS1.0 XRF analyzer Pb Cd Cr Hg Br Cl

EDX-8000 is a popular model in the series of products, triple ray protection system; Humanized operation interface; Comprehensive application of empirical coefficient method, basic parameter method V1.0 analysis software. Element test range from S-U. That is, Br in Pb, CD, Hg, PBB and PBDE in RoHS instruction, Cr in hexavalent chromium and Cl and Br in halogen-free instruction can be controlled. It can fully meet the related control requirements of RoHS/WEEE/ halogen-free. Carefully designed open work curve function, especially suitable for multi-material factory process control.

Original spectrum comparison function, real-time tracking supplier material changes and timely warning, RoHS/ halogen-free and supplier control has unparalleled advantages.

2.Performance advantage

  1. Triple ray protection (logiciel, hardware, maze design) to ensure the operator’s personal safety and radiation damage caused by accidental operation;
  2. Large sample cavity design, suitable for the detection of large samples, partially replacing the handheld XRF function;

The new optical path design solves the negative influence of air optical path on the measurement of Cl element to the maximum extent, and ensures the detection limit and stability of chlorine (Cl) element.

  1. The newly optimized V1.0 analysis software can automatically set the optical tube power according to the sample material, shape and size, which can not only extend the service life of the optical tube but also give full play to the detector performance and greatly improve the measurement accuracy;
  2. The only open working curve calibration platform in the industry, which can tailor the best harmful substances detection and control scheme for users;
  3. integration of a series of advanced spectral processing methods, including FFT (fast Fourier transform filter), accurate background deduction method, derivative automatic peak search and Quasi-Newton(quasi-Newton) optimization algorithm;
  4. International leading XRF analysis software, including the integration of empirical coefficient method, basic parameter method (FP method), theoretical α coefficient method and other classical analysis methods, to fully ensure the accuracy of test data;
  5. Customized test report output format (Excel, PDF, etc.) according to user requirements, in line with a variety of statistical and format requirements of the factory;
  6. Can provide hexavalent chromium quantitative test technology and accessories, coating thickness measurement and multi-element analysis software (users need to purchase separately);
  7. Multi-language software interface is available; Original spectrum comparative analysis method, supplier material changes in time warning function

3.Application areas

Products for RoHS directive control: large household appliances, small household appliances, information technology and communication equipment, outils électriques, toys and other equipment. Products used for halogen-free directive control: products with flame retardants containing Cl, Br and other elements as raw materials.

GA-EDX-8000 ROHS1.0 X-ray Fluorescence Spectrometer

4.Rohs1.0 ROHS six + halogen complete sets of testing equipment list

1.Index technique

Modèle: EDX-8000
Test object: Powder, solide, liquide
Scope of elemental analysis: Sulfur (S) -Uranium (U) (Sodium NA, magnesium MG, aluminum AL, silicon SI, phosphorus P content in silica gel can be measured above 600PPM)
At most measurable elements simultaneously: 36
Range of content analysis: 1ppm to 99.99%
Working stability: The total fluorescence intensity is 0.1%
Test time: Quick measurement: 30s (depending on substrate) Conventional measurement: 100s(depending on substrate)
Minimum detection limit: Pb≤5ppm,Cd/Cr/Hg/Br≤2ppm,Cl≤50ppm
Instrument resolution: 144±5eV
Multichannel analyzer: 2,048 channels
Working conditions: Température de fonctionnement: 10-30℃; Humidité relative: 35% ~ 70%; Source de courant: CA :220V ±5V
Appearance size: 550mm (W) * 410mm(D) * 320mm(H)
Oversized measuring bin: 439*300*50mm;
Poids: About 41.8Kg

 

2.Configuration standard

Configuration Quantité Units
The hardware part of the instrument is mainly configured 1 Set of
1. High-resolution electrical refrigeration semiconductor detector (importé) 1 Set of
2. High Power X-ray tube (importé) 1 un
3. High voltage power supply (importé) 1 un
4. 2,048 digital multichannel analyzer 1 Set of
5 High precision CCD 1 un
6. Filter: 5 kinds of composite filter automatic switching 5 groupe
7. Collimator: with a diameter of 8.0mm, 6.0mm, 4.0mm, 3.0mm, 2.0mm, 1.0mm, 0.5mm, 0.2mm 8 un
Instrument peripheral configuration
1.Computer: HP Business computer 1 Set of
2.HP color inkjet printer 1 Taïwan
3. Silver correction piece 1 slice
4 .Plastic standard sample: EC681M 1 slice
5 .Sample cup, Mylar membrane A number of
6.Software configuration
7.RoHS/ Halogen analysis software/Heavy metal detection/plating Facultatif Set of

GA-EDX-8000 ROHS1.0 X-ray Fluorescence Spectrometer

5.EDX-8000 main accessories detailed parameter configuration

5.1 Detection System

Taper: Si-PIN detector

Be window Thickness: 1mil(0.0254mm)

Best resolution: 144±5eV

System peak-to-back ratio: ≥ 6200/1

Energy response range: 1keV ~ 40keV Recommended count rate: 5000cps

5.2 Tube à rayons X

Tension : 0 ~ 50 kV

Maximum current: 1.0 mA

maximum d'énergie: 50W

Filament voltage: 2.0V

Filament current: 1.7UN

Ray extraction Angle: 12°

Target : MO

Be window thickness: 400un

5.3 High-voltage Power Supply

Tension d'entrée: DC +24V±10%

Courant d'entrée: 4.25UN (Max.)

Tension de sortie: 0-50Kv & 1mA

maximum d'énergie: 50W

Voltage adjustment: 0.01% (from no load to full load)

Current adjustment: 0.01% (from no load to full load)

Ripple voltage: Under the condition of output rated voltage, the peak ripple voltage is 0.25% of the highest output voltage.

8-hour stability: ≤0.05%

5.4 Fretting platform

Load test platform, fine tuning device outside the instrument, combined with 1.3 million pixels of high-definition CCD, accurate positioning of the test sample, to prevent the sample is placed after the sample cover closed vibration and change the test position, resulting in inaccurate testing;

5.5 High resolution CCD

1.3 megapixel HD CCD camera can effectively observe the condition of the test area in real time, and take photos of the material as part of the test report.

5.6 Heat dissipation system

Efficient three-dimensional cooling system, greatly provide the reliability and stability of the instrument.

5.7 Radiation safety system

Triple ray protection system (logiciel, hardware, labyrinth design), open cover test automatic warning system

 

6.Instrument software configuration

6.1Instrument operating software function

1.Software interface

2.Caractéristiques fonctionnelles

1.The five harmful elements in the RoHS directive and the halogen-free requirements (Pb, CD, Hg, Br, Croisement, Cl) can be accurately tested;

Preset multiple working curves, covering metal, PE, PVC, aluminum magnesium, solder, copper alloy and other matrix types can meet the requirements of users’ routine measurement;

2.Provide an open working curve platform, users can freely configure the working curve and add any standard sample data, in order to meet the requirements of higher testing degree, or adapt to the later expansion of environmental protection directives;

3.Accurate data processing method: based on the basic parameter method, the filter system with accurate configuration greatly improves the peak to back ratio, combined with a series of advanced spectral processing methods, greatly improves the detection accuracy of characteristic spectral lines, and then further correction with the empirical coefficient method as a basis, so that the test data can achieve extremely high precision and accuracy;

4.Data management: the professional report generation, query printing, operator classification authorization and other functions supported by the database are greatly convenient for enterprise management;

5.Perfect safety interlocking function: with the protective measures of the hardware circuit, the X-ray is automatically cut off when the unsafe operation occurs to ensure that the operator is not hurt;

6.Intelligent software protection, to avoid improper operation of the spectrometer damage, prolong the instrument life.

7.Stability self-test function: it can automatically detect the current stability of the instrument in real time;

8.Operation interface language: Anglais, Chinois;

Original spectrogram comparative analysis method, supplier material changes in time warning function

 

7.The peripheral equipment of the instrument

Instrument standard equipment parameters

Computer : Lenovo brand computer, Modèle: Yangtian M4900t-00

Memory: 4g

Processor: Dual-core processor

Hard drive: 1T

Monitor 19.5LCD

The instrument comes with accessories and technical data

Eu standard E60K one silver calibration sample one

Two sample cups

Test film 50 pièces

Five safety tubes

One copy of the warranty card

One copy of certificate of conformity

One copy of instrument operating manual