Cone and Plate Viscometers
Most of paint and coatings are non-Newtonian fluids, its viscosity would show typical changes when applied with roller, brush or spray gun under high shear rates.
BGD 159 series Cone and Plate Viscometers designed by ISO 2884, ASTMD 4287 et BS 3900, can offer from 10,000S-1 to 12,000S-1 shear rates.
Viscosimètres à cône et à plaque BGD159
Caractéristiques
◆ 7 inch touch screen with powerful human-computer interactive interface and rich information, facile à utiliser
◆ Interchangeable cones, simple to install and easy to clean
◆ Choice of shear rate. Standard speeds include 750 et 900 rpm to provide shear rate at 10,000 sec-1.
◆ only need small sample amount(< 1 mL), simplifies testing
◆ Build-in PT100 temp. sonde
◆ ARM chip processor and Gigabit Ethernet port ensure higher data processing speed and rapid& stable data transfer
◆ New designed durable axle, anti-static shell and metal lifter
◆ Come with heating and temp. control system, can set sample plate temperature from -5°C to 120°C or RT+5°C to 300°C
◆ Variety of viscosity units and auto switch between dynamic and kinematic viscosity
◆ Calibration by user:temperature and correction factor protected by password
Viscosimètres à cône et à plaque BGD159
How to choose your suitable Viscometer?
1. Specify one speed or shear rate if this is required for your method.
2. Indicate viscosity range.
3. Select the temperature range that best suits your application: -5°C to 120°C (L Type) or RT+5°C to 300°C (H Type)
4. Choose from 10 cones for multiple viscosity ranges
Viscosimètres à cône et à plaque BGD159
Principaux paramètres techniques
| Informations de commande →
Paramètres ↓ |
BGD 159/1
(400 RPM) |
BGD 159/2
(750 RPM) |
BGD 159/3
(900 RPM) |
BGD 159/4
(@5-1000 RPM) |
| Cone No.:CAP-01 Shear Rate:13.3N Sample Volume:67μL |
47-469
mPa.s |
25-250
mPa.s |
20-208
mPa.s |
20-37,500
mPa.s |
| Cone No.:CAP-02 Shear Rate:13.3N Sample Volume:38μL |
90-938
mPa.s |
50-500
mPa.s |
40-417
mPa.s |
37-75,000
mPa.s |
| Cone No.:CAP-03 Shear Rate:13.3N Sample Volume:24μL |
180-1,875
mPa.s |
100-1,000
mPa.s |
80-833
mPa.s |
75-150,000
mPa.s |
| Cone No.:CAP-04 Shear Rate:3.3N Sample Volume:134μL |
300-3,750
mPa.s |
200-2,000
mPa.s |
170-1,667
mPa.s |
150-300,000
mPa.s |
| Cone No.:CAP-05 Shear Rate:3.3N Sample Volume:67μL |
600-7,500
mPa.s |
400-4,000
mPa.s |
300-3,333
mPa.s |
300-600,000
mPa.s |
| Cone No.:CAP-06 Shear Rate:3.3N Sample Volume:30μL |
1,500-18,750
mPa.s |
1,000-10,000
mPa.s |
800-8,333
mPa.s |
750-1,500,000
mPa.s |
| Cone No.:CAP-07 Shear Rate:2.0N Sample Volume:1700μL |
78-787
mPa.s |
N/A | N/A | 32-63,000
mPa.s |
| Cone No.:CAP-08 Shear Rate:2.0N Sample Volume:400μL |
313-3,125
mPa.s |
N/A | N/A | 125-250,000
mPa.s |
| Cone No.:CAP-09 Shear Rate:2.0N Sample Volume:100μL |
1,250-12,500
mPa.s |
N/A | N/A | 500-1,000,000
mPa.s |
| Cone No.:CAP-010 Shear Rate:5.0N Sample Volume:170μL |
100-1,250
mPa.s |
N/A | N/A | 50-100,000
mPa.s |
NOTE:
1. “N”=Rotor Speed
2. Each Ordering Information has two different types according to temperature range:-5°C to 120°C (L Type) or RT+5°C to 300°C (H Type)
Viscosimètres à cône et à plaque BGD159
Opptional Accessories
Série THD—Bain thermostatique basse température
1600 BGD—Huile standard (500 ml)
BGD1601—Low Viscosity Adapter(The 0th rotor and can measure 1.0 mPa.s sample)
BGD1602—Adaptateur pour petits échantillons (il est spécialement conçu pour les clients ayant de petits échantillons et ne nécessite qu'une quantité aussi petite que 5 ~ 18 ml);La coupelle à échantillon se nettoie facilement, installé, supprimé, et observé;Des données précises sur le taux de cisaillement et la contrainte de cisaillement peuvent être obtenues pour une analyse minutieuse des caractéristiques du fluide de l'échantillon;Des gobelets d'échantillons uniques sont disponibles)
BGD 1603—Mini Single Color Printer
BGD 1604—RTD Thermometer(-20℃~150℃)
BGD 1605—Thermos (Il a été conçu pour mesurer avec précision la viscosité de l'huile chauffée, paraffine, émulsions d'asphalte, médecine, matériaux liquides à haute teneur en polymères et similaires à haute température. Il permet de contrôler la température d'un échantillon dans une plage de température ambiante de +300 ℃. Il peut programmer le thermostat intelligent et assurer sa fluctuation de température dans les 0,1 ℃. La dose d'échantillon est aussi petite que 10 ml, et des gobelets d'échantillons uniques sont disponibles. Le type standard de broche SC4 peut être appliqué, ce qui est facile à utiliser)
BGD 1607—BGD 155 Viscometer data collection and graphing software(Automated data collection; resulting in viscometer graph, and recording measuring data each time;Allowing comparison of at most 10 history data;Output Excel documents)
BGD 1608—BGD 156-157-158 Viscometer data collection and programmed analysis software(Automated data collection and testing; resulting in viscometer graph, and recording measuring data each time;Allowing comparison of at most 10 history data;Output Excel documents;Programmable downloading, Offline working;Analyses data, draw charts and print)