Insulation Resistance Tester

Under the condition of without using of an external voltage source, AT682/AT683x has high-cost performance and provides the shortest response time which completely surpasses simulation meter.

Insulation Resistance Tester

SPECIFICATIONS
 

AT682

AT683

AT6830/6833 (customized for equipment factory)

Paramètres

Leakage current and insulation resistance

La resistance d'isolement

Output Voltage

AT682, AT683: (NC)1V~1000VDC

AT6830: 50V,100V,250V,400V,500V

AT6833: 50V,100V,250V,400V,500V, 1000V

Précision de base <10g: 3% ≥10G: 5% ≥100G: 10%
Mesures Gamme 10kW~1TW (104~1012W)

10V: 10kW~10GW

100V: 100kW~100GW

1000V: 1MW~1000GW

100kW~10TW

10V: 100kW~100GW

100V: 1MW~1TW

1000V: 10MW~10TW

50kW~500GW (104~1011W)

50V: 50kW~50GW

500V: 500kW~500GW

AT6833: 1000V: 1MW~1000GW

Display Max 9999
Gamme

Automatic and Manual

Vitesse

55 fois/seconde,15 fois/seconde,3 fois/seconde

Adjustment

Open-circuit Zero-Adjust for each range

Result Display

Montrer, actuel, resistance, peak value, tri des résultats

None

Charging Timer

999.9s

None

Comparateur

30 sets record,GD/NG Beep:DG,NG,OFF setting

1 set record, HI/LO NG beep

Interface

RS-232C interface, Handler interface

Autres VFD 4 color high-definition screen, keypad-lock, data hold Precharging: 500mA
GENERAL FEATURES
Source de courant

AT682, AT683: Tension: 198VAC~240VAC, Fréquence:50Hz, Pouvoir: Max 30VA

AT6830/6833: Tension:198VAC~240VAC, Fréquence:50Hz, Pouvoir:200Virginie

Taille

AT682, AT683: (mm)264(Largeur)x107(Hauteur)x350(Depth), 5kg

AT6830/6833: (mm) 445 (Largeur)x129 (Hauteur)x351 (Depth), 8kg

ORDERING INFORMATION
Accessoires

ATL507 Test clip

ATL108 RS232 communication cable

AC Power Cord