Testeur de résistance d'isolation AT682
- Description
- Enquête
Description
Insulation Resistance Tester
Under the condition of without using of an external voltage source, AT682/AT683x has high-cost performance and provides the shortest response time which completely surpasses simulation meter.
Insulation Resistance Tester
| SPECIFICATIONS | ||||
|
AT682 |
AT683 |
AT6830/6833 (customized for equipment factory) |
||
| Paramètres |
Leakage current and insulation resistance |
La resistance d'isolement |
||
| Output Voltage |
AT682, AT683: (NC)1V~1000VDC AT6830: 50V,100V,250V,400V,500V AT6833: 50V,100V,250V,400V,500V, 1000V |
|||
| Précision de base | <10g: 3% ≥10G: 5% ≥100G: 10% | |||
| Mesures Gamme | 10kW~1TW (104~1012W)
10V: 10kW~10GW 100V: 100kW~100GW 1000V: 1MW~1000GW |
100kW~10TW
10V: 100kW~100GW 100V: 1MW~1TW 1000V: 10MW~10TW |
50kW~500GW (104~1011W)
50V: 50kW~50GW 500V: 500kW~500GW AT6833: 1000V: 1MW~1000GW |
|
| Display Max | 9999 | |||
| Gamme |
Automatic and Manual |
|||
| Vitesse |
55 fois/seconde,15 fois/seconde,3 fois/seconde |
|||
| Adjustment |
Open-circuit Zero-Adjust for each range |
|||
| Result Display |
Montrer, actuel, resistance, peak value, tri des résultats |
None |
||
| Charging Timer |
999.9s |
None |
||
| Comparateur |
30 sets record,GD/NG Beep:DG,NG,OFF setting |
1 set record, HI/LO NG beep |
||
| Interface |
RS-232C interface, Handler interface |
|||
| Autres | VFD 4 color high-definition screen, keypad-lock, data hold | Precharging: 500mA | ||
| GENERAL FEATURES | ||||
| Source de courant |
AT682, AT683: Tension: 198VAC~240VAC, Fréquence:50Hz, Pouvoir: Max 30VA AT6830/6833: Tension:198VAC~240VAC, Fréquence:50Hz, Pouvoir:200Virginie |
|||
| Taille |
AT682, AT683: (mm)264(Largeur)x107(Hauteur)x350(Depth), 5kg AT6830/6833: (mm) 445 (Largeur)x129 (Hauteur)x351 (Depth), 8kg |
|||
| ORDERING INFORMATION | ||||
| Accessoires |
ATL507 Test clip ATL108 RS232 communication cable AC Power Cord |
|||