Solution d'analyse de l'épaisseur du revêtement –Rapport d'application du spectromètre EDX800OT PLUST PLUS
An introduction
Film thickness meter EDX8000T Plus product features
The new downshot integrated design
Fast testing, no sample preparation required
The built-in HD CCD camera can be used to observe and select the measurement of the thickness of the coating in small areas to avoid direct contact, contamination or damage to the measured object. The software is equipped with distance correction algorithm to realize the difference of irregular samples (such as concave and convex surface, thread, surface courbe, etc.)Accurate testing of the profile
A variety of standard samples are available for coating thickness measurement and composition analysis
Can cover the periodic table Mg magnesium to U uranium
SDD detector with high counting range and excellent energy resolution
Automatic switching collimator and filter (0.15mm,0.2mm,0.3mm)
Solution d'analyse de l'épaisseur du revêtement –Rapport d'application du spectromètre EDX800OT PLUST PLUS
XRF coating thickness gauge working principle
The EDX8000T Plus is a coating thickness gauge that irradiates X-rays onto the sample and measures the thickness of metal films such as the coating by the strength of the second X-ray reflected off the sample, which will not cause damage to the sample because it is not in contact with the sample and the X-ray energy that is irradiated on the sample is very low. En même temps, the measurement can also be completed in 10-30 secondes.
Solution d'analyse de l'épaisseur du revêtement –Rapport d'application du spectromètre EDX800OT PLUST PLUS
Typical application directions:
Coating thickness analysis
Chrome plating, such as plastic products with decorative chrome plating finishes
Anticorrosive coatings such as zinc on steel
Coatings on circuit boards and flexible PCBS
Contact surfaces for plugs and electrical contacts
Plating solution analysis
Analysis of rhodium materials on precious metal coatings such as gold substrates
Plating solution analysis
Analysis of functional coatings for the electronics and semiconductor industries
Analyze hard material coatings such as CrN,TIN or TiCN2 Instrumentation and application technical requirements
Instrument: EDX8000T PLUS X-ray fluorescence spectrometer
Application information: The substrate can be plastic or metal. The coating material must be metal. The coating can be pure metal or alloy. Pure metal can be used to establish new calibrations for different coating materials. Software based on the basic parameter algorithm (FP program) allows the instrument to measure not only the coating thickness of each layer, but also the elemental chemical content of each layer.
Solution d'analyse de l'épaisseur du revêtement –Rapport d'application du spectromètre EDX800OT PLUST PLUS
Measuring parameters
| Tube voltage | Tube current | Filter | Collimator | Test time |
| 40kv | 600faire | AI | 0.5mm | 100s |
Three testable maximum number of layers and error analysis:
1. Maximum 5 layers at the top of the substrate. Chemical composition analysis for each layer ranges from 5ppm to 100%
2. Detection limit of coating thickness: 0.01µm
3. Précision: from top layer to bottom layer
The first layer is ±5%
The second layer is ±10%
The third layer is ±20%
The fourth layer is ±25%
The fifth layer is ±30%
Penetration depth of EDXRF using a 50 watt X-ray tube
Solution d'analyse de l'épaisseur du revêtement –Rapport d'application du spectromètre EDX800OT PLUST PLUS
| XRF penetrable thickness gauge | ||
| Coating material | Base material | Épaisseur (μml) |
| AI | Cu | 0-100.0 |
| cd | Fe | 0-60.0 |
| cu | Al | 0-30.0 |
| cu | Fe | 0-30.0 |
| cu | Plastic | 0-30.0 |
| Au | Ceramic | 0-8.0 |
| Au | Cu/Ni | 0-8.0 |
| pb | Cu/Ni | 1-15.0 |
| Dans | Ceramic | 0-20.0 |
| Dans | Cu | 0-20.0 |
| Dans | Fe | 0-20.0 |
| pd | Dans | 0-40.0 |
| pd-Ni | Dans | 0-20.0 |
| pt | De | 0-8.0 |
| Rh | Cu/Ni | 0-50.0 |
| Agir | Cu/Ni | 0-50.0 |
| Sn | Al | 0-60.0 |
| Sn | Cu/Ni | 0-60.0 |
| Sn-pb | Cu/Ni | 0-25.0 |
| Zn | Fe | 0-40.0 |
Four copper nickel tin plating spectrum and test results are as follows
The spectrum and test results of iron, copper and tin plating are as follows
Solution d'analyse de l'épaisseur du revêtement –Rapport d'application du spectromètre EDX800OT PLUST PLUS
5. Customizable test reportsSample type Copper gold plating Three consecutive test reports: base copper, plating pure gold
Six conclusionsAccording to the above coating test performance and report, it can be concluded that EDX-8000T PLUS series XRF can be used to analyze the coating thickness of different materials and identify the chemical composition content of materials at the same time.