- Descripción
- Consulta
Descripción
Detector de fugas de gas SF6 XP-1A
Introducción del producto
XP-1A SF6 gas qualitative leak detector is an advanced microprocessor. The digital signal processing technology it uses makes it possible to be better than the control circuit and sensing head signal used. Además, the number of components used in the circuit is reduced by approximately 40%, which improves reliability and performance. The microprocessor monitors the sensor head and battery voltage values in real time up to 4,000 veces por segundo, compensating for even the tiniest changes in signal pulsations. This makes the instrument a stable and reliable inspection tool in almost all environmental applications.
The XP-1A SF6 gas qualitative leak detector has been designed to add a number of user-friendly features. Seven levels of sensitivity free setting, so that the instrument from one to seven to increase the sensitivity of 64 veces; Unique tricolor leds indicate progressive and wide leakage sizes; Indicating the level of sensitivity; The actual voltage indication of the battery level is also provided. Touch keyboard to control all functions; Novel shell design for users to grip, fácil de operar; Visual indicator for installation and use.
Caracteristicas de producto
1. Unique sensitivity adjustment
2, original tracking leakage point
3. Pantalla de energía
4, operación simple, fácil de cargar
5, full intelligence
6, anti-pollution, anti-interferencia
7. Buena repetibilidad
8, velocidad de respuesta rápida
9, alta sensibilidad, high stability microprocessor control, with advanced digital signal processing
10, three color visual display
11, including noise suppression characteristics
12, seven levels of sensitivity, providing up to 64 times the order of magnitude
13, cordless and portable, with two C battery operation
14, touch keyboard control
15. Include a carrying box
16, real-time sensitivity adjustment
Detector de fugas de gas SF6 XP-1A
| Fuente de alimentación | 3En DC, two C alkaline batteries |
| maximum sensitivity | According to SAEJ1627 verification criteria, the guaranteed value for R12, R22 and R134a is 14 g/year |
| limiting sensibility | For SF6 and all halogen-based refrigerants <3 g/year |
| Temperatura de funcionamiento | 0-52℃ |
| battery life | Normal use about 30 horas |
| load cycle | Continuous, ilimitado |
| response time | instant |
| reset time | 1 segundo |
| tiempo de precalentamiento | Aproximadamente 2 segundos |
| installation weight | 560 gramos |
| Tamaño del dispositivo | 22.9cm×6.5cm×6.5cm |
| Probe length fixing | 35.5cm |