Descripción

Inductance Meter

Características
100Hz,120Hz,1kilociclos,10kilociclos 4 typical test frequencies
4.3 inch TFT liquid crystal display, chino e ingles
optional operation interface
6-digit reading resolution

Maximum test speed:12.5EM, support low frequency and high
velocidad:TX4+3ms
10 clasificación de contenedores, test sorting is more perfect
100 sets of LCRZ instrument setting files, 10 medidas
Soft power switch
Support 110V/220V two power supply voltages
10-point list sweep, support multi-frequency test sorting
Ultra-low signal source output offset (<100μV), meeting the
needs of large inductor, common mode choke inductor test
Super impact protection
Power on state lock button;
Empty fixture judgment
Función de registro de datos
Screen capture function
Interface function, momento, trigger delay, etc.. are more complete

Inductance Meter

Parámetro técnico

Modelo TH2810B+
Precisión básica 0.1%
Frecuencia de prueba 100Hz,120Hz,1kilociclos,10kilociclos
Parámetros de prueba l, C, R,z|, D, q, X, d, tr, Vm, Soy, %
V/I Monitor
AC Test Signal Level 0.1Vrms,0.3Vrms,1Vrms
Signal Source Internal Resistance 10Oh, 100Oh
Test Terminal Configuration 5-Terminal
Prueba de velocidad(ms/tiempo) Rápido: 19EM; Medio:83EM; Lento: 333msF≤120Hz Fast :4XT+3ms
Compensación cero Abierto, Short, Carga
Barrido de lista 10-point list sweep; Each scan point can be individually sorted, support multi-frequency combined test sorting; Scanning test for frequency and AC voltage
EquivalentCircuit Series, Parallel
Modo de rango AUTO, SOSTENER
Modo de disparo Interno, Externo, Manual, Bus
Tiempos promedio 1-255
Arithmetical Operation lectura directa, abdominales,%
Delay Retardo de disparo, step delay: 0—60.000s, 1ms step
Función general Series, parallel equivalent mode, calibración: circuito abierto, cortocircuito, range selection: automático, manual, trigger mode: EN T, HOMBRE,EXT, AUTOBÚS, keyboard lock function
Comparador 10 clasificación de contenedores,BIN1-BIN9,NG,A; Bin count function PASS, FALL front panel LED display
Nonvolatile Storage 100 sets of LCRZ instrument setting files, 10 test results
External USB Storage Instrument setting file, CSV data file

 

Modelo TH2810D TH2811D
Measurement Function
Test Parameter L-Q, C-D, R-Q,z|-q
Precisión básica 0.1% 0.2%
Equivalents Circuit Series, parallel
Mathematical Functions Deviation and PercentDeviation ——
Rang Mode Auto, Sostener
Modo de disparo Interno, Manual andExternal Interno
Velocidad de medición Rápido: 12, Con: 5.1, Lento: 2.5 (meas/ sec)
Correction Function Open/Short multi-frequency Zeroing
Measurement Terminals Five Terminals
Señal de prueba
Frecuencia de prueba 100Hz,120Hz,1kilociclos,10kilociclos,Exactitud 0.01%

 

temperatura de operacion & Humedad 0°C – 40°C, ≤90% HR
Requisitos de energía Voltaje 99V – 121V, 198V – 242V
Frecuencia 47.5Hz – 63Hz
El consumo de energía ≤20 VA
Dimensiones (Ancho×Alto×Profundidad) 270mmx130mmx300mm
Peso Aprox.. 3.7kg