1. The automatic whip-like electrically tuned antenna system is installed in the host computer and tuned synchronously with the host computer, and the operation of the antenna is omitted. The field strength value can be read directly, and the total weight of the host and antenna is less than 3.5 kg. Suitable for electric power and environmental protection field test.
2. With GPS positioning system, the spatial position, time and field strength value can be read out synchronously.
3, the minimum measured field strength value is less than 20dBμV/m (BW: 9KHZ)
4. The receiver can also be used as a spectrum analyzer to realize multi-angle scanning of spatial electromagnetic field strength.
5, more importantly, it can achieve step by step, discrete, point by point measurement of multiple frequency points or single frequency point of the field strength,
6, the measurement results can be stored in the receiver CF card, and then imported into the computer.
7. When testing the field strength spectrum, it only needs to set the initial frequency, termination frequency and step length to realize the automatic test of the required field strength. The minimum step size is 1KHZ
8. The narrow band whip antenna of KDZD3933 receiver can reject out-of-band signals.
9, the instrument is small, peso ligero, fácil de cargar, fast test speed, fácil de operar, very suitable for field operation measurement use.

EMI Test Receiver

The technical index conforms to GB/T6113.1-1995 CISPR16-1
measurement frequency range 150kHz ~ 30MHz
IF bandwidth 9kilociclos
frequency resolution 1kilociclos
frequency stability 1* 10-6
input impedance 50W.
Standing wave coefficient:
detection mode average quasi-peak peak
terminal voltage measurement range 0dB ~ 120dB(S/N=6dB 1mV=0dB)
terminal voltage measurement error (in the standard working condition) ≤±2dB
field strength measurement range 20dBμV/m-140dbμV/m
mirror frequency and IF suppression >40dB
overload factor in line with CISPR16-1; GB/T6113.1
pulse characteristics in line with CISPR16-1; GB/T6113.1
Detection time constant in line with CISPR16-1; GB/T6113.1
scanning mode scan range, Numero de pie, level threshold can be set
modo de operación automático, manual
modo de visualización Pantalla LCD TFT en color
frequency standard display display level and frequency
Antenna calibration automático
modo de salida CF card output
Software can be configured according to user requirements
fuente de alimentación special external DC power supply or AC 220V (50Hz), power consumption is not more than 70W
the overall size 220mm×230mm×100mm
Weight of host antenna about 3.5kg