Probador de conductividad térmica con método de alambre caliente transitorio KDRX-II ASTM C1113 ASTM D5344

Probador de conductividad térmica con método de alambre caliente transitorio KDRX-II ASTM C1113 ASTM D5344

Descripción

KDRX-II transient hot wire method thermal conductivity tester ASTM C1113 ASTM D5344 Refractory Thermal conductivity tester

1.Introducción del producto

The hot-wire thermal conductivity meter (transient method) is measured using the line source test method of the thermal probe, which has a very large aspect ratio to achieve the simulation conditions of an infinitely long, infinitely thin heat source. Fácil de usar, plug and play probe sensor fast interface mode and simple software interface operation, so that users can quickly grasp and accurately operate. From the time you start preparing the test to the time you get the results, it usually only takes one to two minutes. Wide application range, fast measurement speed, accurate measurement results and other advantages, with small size, fácil de cargar, higher cost performance to meet the needs of production, quality inspection, research and development of related industries.

The instrument conforms to the standard ASTM D5344-2008 “Standard test method for the Determination of Thermal Conductivity of Soil and soft stone by Hot Needle Probe Method”; GB/T 10297-2015 “non-metallic solid materials thermal conductivity determination hot-wire method”; GB/T 11205-2009 “Rubber thermal conductivity determination hot-wire method”; ASTM C1113-2009 “Test method for the Determination of Thermal Conductivity of Refractory Products by Hot Wire”; ASTM D5930-2009 “Standard test method for Measuring Heat Conductivity of Plastics by Instantaneous Linear Source Technique”.

KDRX-II transient hot wire method thermal conductivity tester ASTM C1113 ASTM D5344 Refractory Thermal conductivity tester

2. Product Parameter

thermal conductivity
rango de medicion
0.0001 ~ 50 W/m K; Resolución: 0.00001w/m k0.0001 ~ 50 W/m K; Resolución: 0.00001w/m k
Relative measurement error ≤3%
repeatability error ≤3%
resolución de temperatura 0.01ºC.
tiempo de medición 2 ~ 180 seconds adjustable
sample test
rango de temperatura
-40 ~ 130ºC; Configuración estándar: temperatura ambiente.
According to customer requirements can be equipped with a variety of high and low temperature section control box (-40 ~ 130ºC) or vacuum state of the test state, the contract agreed, the cost of additional;
measurement object el plastico, suelo, soft rock, líquido; Thermal conductivity measurement of paste, partícula, powder and other materials.
sample shape bloquear, hoja, pasta, polvo, partícula, colloid, liquid can be (round, square, irregular shape can be, no limit to the shape), just have a relatively flat sample surface.
Tamaño de la muestra cylindrical sample, diameter ≥ 30mm or 30*30mm square sample or peripheral irregular sample, thickness ≥1mm
external power supply CA 220 V ± 10 %; 50/60 Hz
the machine power <200w
Tamaño del instrumento length 380x width 400x height 165 (milímetros)
peso 5kg