Descripción

Capacitance bridge tester

KDHG-A current transformer field comprehensive tester is a kind of multifunctional field test instrument specially designed for testing transformer: características de voltios-amperios, relación, polaridad, curva de error, calculation inflection point and secondary side loop inspection.

Capacitance bridge tester

METROain feature
1. The maximum voltage output of a single 220V input is 0-2500V, the maximum current output of a single machine is 0-1000A, supporting the detection of 500KV/1A CT, which is very suitable for field maintenance.
2. No external auxiliary equipment is required to complete the test work.
3. High intelligent design, no need to set, Detección automática.
4. Single-phase 220V power supply, fully isolated output, multiple protection, seguro y confiable.
5. Support CT/PT automatic detection, support to detect ratio 1 and ratio 5 current transformer.
6. Single machine to complete the test project, do not need external power supply and other auxiliary equipment.
7. Tecnología de control de potencia MBC, fuente de alimentación de entrada monofásica AC220V, Y la fuente de alimentación de trabajo y la fuente de alimentación comparten un puerto de entrada, El diseño es más científico y razonable., and the use is more safe and reliable.
8. The power output of the equipment is the real voltage and current value, y la forma de onda es la onda sinusoidal estándar, la frecuencia es 50-60Hz; Puede simular eficazmente el estado real del transformador y cumplir con las normas nacionales de mantenimiento pertinentes..
9. It can detect CT/PT voltammetry characteristics, relación, polaridad, 5% y 10% curvas de error, Flujo primario de CT y desmagnetización de CT y otros elementos, which can be easily used in one machine.
10. Single power input port; Solo 8 test ports can complete the CT/PT test project, el modo de conexión es seguro y sencillo, muy adecuado para uso en el campo, Puede reducir eficazmente la intensidad del trabajo y mejorar la eficiencia del trabajo..
11. The thermal printer automatically selects and prints typical report usage data, which is ideal for field data comparison.
12. Chinese menu, gran pantalla LCD, clear interface.
13. Rotate mouse, operación simple.
14. Large capacity FLASH storage: puede ahorrar 1000 groups of test data, no se pierde después de un corte de energía.
15. interfaz USB: Support U disk storage function.
16. Talla pequeña, peso ligero: fácil de usar en el sitio.

Capacitance bridge tester
Función de prueba principal
CT current transformer
Volt-ampere characteristic detection
A flow test
Automatic demagnetization
Power frequency AC withstand voltage test
Ratio measurement
Comparison measurement
Angular difference measurement
Discriminación de polaridad
Automatic calculation of excitation inflection point voltage/current value
Automatically calculate 5% y 10% curvas de error
Secondary AC withstand voltage test
Secondary loop detection
Secondary actual load measurement
Secondary winding resistance measurement

PT voltage transformer
Power frequency AC withstand voltage test
Volt-ampere characteristic detection
Ratio measurement
Comparison measurement
Angular difference measurement
Discriminación de polaridad
Automatic calculation of excitation inflection point voltage/current value
Secondary AC withstand voltage testSingle phase capacitance of a group of shunt capacitors and three phase capacitance of various connection types can be measured simultaneously without disconnecting the wires. Al mismo tiempo, the instrument can also measure the inductance of various reactors, and can also be used as a power frequency current tester.

When measuring the value of capacitance or inductance, the instrument can also display the measured voltage, actual, fuerza, frecuencia, impedancia, phase Angle and other data, so as to better analyze the quality of the test.

Capacitance and inductance tester/Capacitance bridge testing machine/Capacitance current tester
The main functions and characteristics of capacitive and inductance measuring instrument
◆ Power output: The power output adopts PID regulation algorithm for constant current and voltage limiting output, which strengthens the measurement accuracy and stability, and the output short circuit will not damage the instrument.
◆ Single-phase test function: the instrument can measure single-phase capacitors, reactores, resistencias, while single-phase measurement can also choose automatic test, by the instrument automatically judge the type of test.
◆ Three-phase capacitance test function: The instrument has three-phase power output and interface, can be three-phase Y-type connection capacitor, three-phase Yn type connection capacitor, three-phase △ type connection capacitor, three-phase III type connection capacitor for a one-time connection, you can complete the three-phase capacitance test, and the separate phase capacitance test calculation, simple y conveniente, Greatly improve the work efficiency of field users.
◆ Capacitance measurement: accurately set the rated frequency and rated voltage of the capacitor test, and the instrument can automatically calculate the compensation capacity of the capacitor, reducing the calculation amount of on-site personnel.
◆ Test reactance measurement: The instrument can automatically calculate the capacitive reactance, inductive reactance and impedance of the test according to the measurement results, which is convenient for further data analysis on site.
◆ Current test function: The instrument clamp current transformer can be used for current detection alone, which can detect the basic wave RMS value, total harmonic distortion, signal frequency and the content rate of the third, fifth, seventh and ninth harmonics of the current signal, so as to carry out simple power quality analysis of the current signal.
◆ The instrument adopts large screen LCD display, using Chinese menu, Chinese prompt, operación simple.
◆ No power off clock and date display; Data storage is divided into local storage and flash disk storage, in which the local storage can store 200 datos de prueba, and the local storage can be transferred to the flash disk; The flash disk storage data format is Word format, which can be edited and printed directly on the computer.
◆ Thermal printer printing function, rápido, silent.
◆ Human-computer interface is more friendly: the status bar at the top of the screen displays the flash drive insertion status, test status, storage status, etc., when the unconnected device is operated, the corresponding unconnected prompt information is displayed.
◆ Tamaño pequeño, peso ligero, Fácil de llevar y usar.
Secondary actual load measurement
Secondary winding resistance measurement
Automatic demagnetization

Capacitance measuring range and accuracy
Capacitance measurement range 1μF ~ 2000μF
Capacitance measurement accuracy ± (reading ×1% +0.005μF)
Resolución mínima 0.001µF (four significant digits)
Measuring range and accuracy of inductance and resistance
Inductance measurement range 1mH ~ 10H
Resistance measurement range 100mΩ ~ 10kΩ
Precisión de la medición ± reading ×2%
Current measurement range and accuracy
Current measurement range AC 20mA ~ 20A
Precisión de medición actual ± reading ×1%
Voltage measurement range AC 0V ~ 30V