Descripción

Instrumento de medición del ángulo de contacto BGD190

Introducción: Contact Angle, it refers to the tangent line of gas-liquid interface at the intersection of gas, liquid and solid phases. The tangent angle θ between the tangent line on liquid side and the solid-liquid boundary.

Instrumento de medición del ángulo de contacto BGD190 is mainly composed of five parts: fuente de luz, injection unit, sample table, acquisition system and analysis software. The equipment adopts the principle of optical imaging and measures the following parameters by image profile analysis.

◆The wetting behavior of liquid on solid surface, como la difusión, infiltration, absorption, etc.. The static contact angle is measured by sessile drop method.

◆Measurement of advancing contact angle(ACA), receding contact angle(RCA), contact angle lag, rolling angle(tilt platform is required) and dynamic contact angle of material on solid surface.

◆Continuous real-time study and process record of absorbing materials, analysis of contact angle variation curve with time.

◆Contact angle measurements of various special materials, such as powders, superficies curvas, super hydrophobic/ super hydrophilic samples.

◆Test of the contact angle of the material immersed in the liquid by the attachment drop method(quartz sample cell is required).

◆Measurement of surface tension, polarity and dispersion components of various liquid meters by pendant drop method.

◆Count surface free energy and analysis of polar dispersion components.

◆Analyze the adhesion of liquid on solid surface, evaluate the uniformity and cleanliness of solid surface, etc..

Instrumento de medición del ángulo de contacto BGD190

Principales parámetros técnicos

Contact angle measurement range: 0~180°

Contact angle resolution measurement accuracy: ±0.001°

Testing accuracy of contact angle: ±1°

Energía libre superficial: zisman, OWRK, wu, wu 2, Fowkes, Antónov, Berthelot, EOS, Trabajo de adherencia, Wet work, Spreading coefficient.

Dynamic contact angle fitting: batch screenshot fitting, video continuous automatic fitting and automatic online real-time fitting.

Surface/interface tension test: Pendant Drop method(real-time full-automatic dynamic surface tension test)

Droplet state test: Gota colgante, Gota sésil(2/3 estado), Captive Bubble, Gota sésil, Sessile Needle

Advancing contact angle & receding contact angle: method of increase and reduce the drop volume automatically measures the change of advancing angle and receding angle.

Spectrogram shows: left contact angle, right contact angle and average contact angle

Unidad de inyección: special precision syringe with capacity of 500μL, hand-operated rotary liquid inlet(the drop accuracy can reach 0.1μL), the movement range of the injection unit is 50mm up and down, 50mm left and right.

Instrumento de medición del ángulo de contacto BGD190

Ajuste del sistema de adquisición.: front and rear 60mm, adjustable viewing angle

Working table size: 120mm×150mm

máx.. width of sample: 200milímetros (unlimited length)

Adjustable range of working table movement(manual, precisión 0,1 mm): forward and rear stroke 60mm, left and right stroke 35mm, up and down stroke 80mm

Configuración estándar: digital camera CMOS, high-definition constant-magnification light tube, video cable, dongle, supporting software, cable de alimentación, micro-sampler, round horizontal ball, sendos; stainless steel needle(equipped with micro-injector), 0.51mm plastic needle(equipped with 1ml syringe), 1.6mm plastic tension needle(equipped with 1ml syringe), and five hex wrenches respectively; ten 1ml syringes

Accesorios Opcionales: thin film fixture, standard film, sample cell, hydrophobic treatment solution, quantitative injection pump, temperature control platform, vacuum platform, electrostatic fan, manual tilt platform, micro injection pump, needle syringe, high-speed camera

Información sobre pedidos: BGD 190—-Instrumento de medición de ángulo de contacto

Instrumento de medición del ángulo de contacto BGD190

Características

◆Conform to standards: ASTM D724-99(R-2003), ASTM D5946-2004, ISO15989, etc.

◆The host adopts the high-strength aviation aluminum alloy structure to be matched with the modular design concept and self-developed integrated chip circuit control, which can be comparable to similar international top brands.

◆Adopt industrial dense adjustable LED cold light source system (life span more than 25000 horas). The uniform light emission ensures clearer imaging and avoids droplet volatilization caused by additional heat.

◆The injection unit adopts micro manual button injection, which is stable and accurate.

◆The three-dimensional manual fine tuning platform is adopted, which is flexible in operation and accurate in positioning. The sample table can be customized according to the actual sample size.

Instrumento de medición del ángulo de contacto BGD190

Características

◆Conform to standards: ASTM D724-99(R-2003), ASTM D5946-2004, ISO15989, etc.

◆The host adopts the high-strength aviation aluminum alloy structure to be matched with the modular design concept and self-developed integrated chip circuit control, which can be comparable to similar international top brands.

◆Adopt industrial dense adjustable LED cold light source system (life span more than 25000 horas). The uniform light emission ensures clearer imaging and avoids droplet volatilization caused by additional heat.

◆The injection unit adopts micro manual button injection, which is stable and accurate.

◆The three-dimensional manual fine tuning platform is adopted, which is flexible in operation and accurate in positioning. The sample table can be customized according to the actual sample size.

Instrumento de medición del ángulo de contacto BGD190

Principales parámetros técnicos

Contact angle measurement range: 0~180°

Contact angle resolution measurement accuracy: ±0.001°

Testing accuracy of contact angle: ±1°

Energía libre superficial: zisman, OWRK, wu, wu 2, Fowkes, Antónov, Berthelot, EOS, Trabajo de adherencia, Wet work, Spreading coefficient.

Dynamic contact angle fitting: batch screenshot fitting, video continuous automatic fitting and automatic online real-time fitting.

Surface/interface tension test: Pendant Drop method(real-time full-automatic dynamic surface tension test)

Droplet state test: Gota colgante, Gota sésil(2/3 estado), Captive Bubble, Gota sésil, Sessile Needle

Advancing contact angle & receding contact angle: method of increase and reduce the drop volume automatically measures the change of advancing angle and receding angle.

Spectrogram shows: left contact angle, right contact angle and average contact angle

Unidad de inyección: special precision syringe with capacity of 500μL, hand-operated rotary liquid inlet(the drop accuracy can reach 0.1μL), the movement range of the injection unit is 50mm up and down, 50mm left and right.

Ajuste del sistema de adquisición.: front and rear 60mm, adjustable viewing angle

Working table size: 120mm×150mm

máx.. width of sample: 200milímetros (unlimited length)

Adjustable range of working table movement(manual, precisión 0,1 mm): forward and rear stroke 60mm, left and right stroke 35mm, up and down stroke 80mm

Configuración estándar: digital camera CMOS, high-definition constant-magnification light tube, video cable, dongle, supporting software, cable de alimentación, micro-sampler, round horizontal ball, sendos; stainless steel needle(equipped with micro-injector), 0.51mm plastic needle(equipped with 1ml syringe), 1.6mm plastic tension needle(equipped with 1ml syringe), and five hex wrenches respectively; ten 1ml syringes

Accesorios Opcionales: thin film fixture, standard film, sample cell, hydrophobic treatment solution, quantitative injection pump, temperature control platform, vacuum platform, electrostatic fan, manual tilt platform, micro injection pump, needle syringe, high-speed camera

Información sobre pedidos: BGD 190—-Instrumento de medición de ángulo de contacto

BGD 190 Instrumento de medición de ángulo de contacto