Conocimiento

Non-destructive determination of silver content in silver products by energy dispersive X-ray fluorescence spectrometer EDX6000

We excited the sample with a 50-watt X-ray tube; Spectrometer for the non-destructive rapid determination of silver content in silver ornaments, tableware, ornaments, silver content in the range of 5.00%~99.99%6, the measurement accuracy and accuracy can meet the actual detection error requirements. The results are consistent with the results of...

Leer más...

Determinación de 15 rare earth components in mixed rare earth oxides in Nanfang ore and Baotou ore by X-ray fluorescence spectrometry EDX9000B ore analyzer

EDX-9000B PLUS XRF Spectrometer Energy dispersive X-ray fluorescence spectrometer Special analyzer for mineral oresKey Advantages Major advantage Advanced made Peltier Electric Refrigeration FAST SDD silicon drift detector The vacuum optical path is equipped with thin film filter technology to improve the detection limit of light elements 40 elements can be analyzed at the same time Can analyze...

Leer más...

X-ray energy dispersive fluorescence spectrometer XRF test using steps

Preparation of the Spectrometer a) Energize the instrument, heat the equipment according to the working guide of the instrument, and stabilize the instrument according to the manufacturer's instructions. b) Ensure the stability of the test and make the detector stable according to the manufacturer's instructions 2 Calibrate a) Select the reference sample as described...

Leer más...

Serie de preguntas frecuentes sobre espectrómetros de fluorescencia de rayos X 2

Preguntas frecuentes de los clientes sobre el espectrómetro XRF: 1. Cómo mantener la dispersión de energía XRF ? ¿Qué se debe hacer con los tubos de rayos X cuando no se realizan análisis de muestras?? Principalmente espectrómetro con temperatura y humedad constantes. (acerca de 22 grados, humedad debajo 60%), ambiente limpio, fuente de alimentación estable, evitar vibraciones. When the...

Leer más...

CEI 62321- Procedure for determination of concentrations of six substances restricted to use in electrical and electronic products (dirigir, cadmio, mercurio, hexvalent chromium, bifenilos polibromados, Éteres de difenilo polibromados) -RoHS test procedure

RoHS compliance testing IEC 62321- Procedure for determination of concentrations of six substances restricted to use in electrical and electronic products (dirigir, cadmio, mercurio, hexvalent chromium, bifenilos polibromados, Éteres de difenilo polibromados) -RoHS test procedure Procedure for determination of concentrations of the six substances limited to use in electrical and electronic products (dirigir,...

Leer más...