The basic principle of XRF fluorescence spectrometer
EDX6000X-ray fluorescence (RFA) gold meter EDX6000 is a diagnostic non-destructive testing technology that can be used to detect and measure the concentration of elements in a substance. Fluorescence is the phenomenon of absorbing incident radiation and re-radiating it as low-energy radiation. An example of fluorescence is a “T” shirt, ultraviolet light that glows noticeably when exposed to an invisible environment. Certain minerals fluoresce; They fluoresce – emit visible light – when exposed to ultraviolet light. At the atomic scale, visible light fluorescence is caused by the ejection of low-energy electrons from the outer electron shell of an atom by incident ultraviolet light. It is left vacant, filled by the electrons that are ejected, by the electrons that “fall” in from the outermost shell. This “insertion” releases a specific amount of energy color (Energie) in the form of some visible light.
In X-ray fluorescence, the same principle applies, but the incoming energy radiates much higher. Instead of exposing the substance to ultraviolet radiation, observe visible light fluorescence, exposing the substance to X-rays and fluorescing emits lower energy X-rays.At the atomic scale, X-ray fluorescence is caused by incident X-rays emitted by high-energy electrons from the innermost electron shell of an atom. The ejected electrons left vacant are filled with electrons that “fall” in from the shell. This “insertion” takes the form of a characteristic X-rayA specific amount of energy is released. The discrete energy of a fluorescent X-ray is the energy level of an electron shell in a “Merkmal” Element. These energy levels are different for each element. daher, by analyzing the energy of the fluorescent X-ray spectrum emitted by an emitter, one can determine which elements are present, and their concentration in the substance. This information may be sufficient to identify the substance.
The basic principle of XRF fluorescence spectrometer
Gold jewelry detection expert EDX6000 gold meter
Instrument parameters
Instrument appearance size: 400mm*405mm*455mm
Sample chamber: 300mm*310mm*104mm
Gewicht des Instruments: 38 kg
Elemental analysis range: K19-U92 Potassium to uranium
Analyzable content range: 1PPM-99,99%
Detektor: AmpTek High resolution electrically refrigerated Silicon detector Si-Pin
Multi-channel analyzer :4096 channel DPP analyzer
Röntgenröhre: 50W high power beryllium window light tube
High voltage generator: maximum output voltage 50kV, with voltage overload protection
Stromspannung: 220ACV 50/60HZ
Umgebungstemperatur: -10° C to 35° C
Instrumentenkonfiguration
Standard Configuration
Optional Configuration
The basic principle of XRF fluorescence spectrometer
Pure Au initializes standard sample AC purified regulated power supply
Ring sample clip gold standard sample
USB cable
Power cable
Test film
Instrument factory and calibration report
Warranty Card