Beschreibung

GA-9002 Touchscreen-Sauerstoffindextester

Design standard:

GB/T 2406.2-2009

GA-9002 Touchscreen-Sauerstoffindextester

Advantages

  1. Full-color touch screen control, just set the oxygen concentration value on the touch screen, the program will automatically adjust to the oxygen concentration balance and issue the sound of beep, eliminating the trouble of manually adjusting the oxygen concentration;
  2. The stepping proportional valve greatly improves the control accuracy of the flow, and the closed-loop control is adopted. Während des Tests, the oxygen concentration drift program automatically adjusts back to the target value, which avoids the disadvantage that the traditional oxygen index tester cannot adjust the oxygen concentration during the test and greatly improves the test accuracy.

GA-9002 Touchscreen-Sauerstoffindextester

Wichtigste technische Parameter

  1. Using imported oxygen sensor, digital display oxygen concentration without calculation, more accurate and more accurate, range 0-100%
  2. Digital resolution: 0.1%
  3. Meßgenauigkeit: 0.1 Ebene
  4. The touch screen setting program automatically adjusts the oxygen concentration
  5. One-key calibration accuracy
  6. One-bond ratio concentration
  7. Stable oxygen concentration automatic alarm sound
  8. With timing function
  9. Experimental data can be stored
  10. Query historical data
  11. Historical data can be cleared
  12. Optional whether to burn 50mm
  13. Air source fault prompt
  14. Oxygen sensor fault prompt
  15. Tips for wrong connection of oxygen and nitrogen
  16. Oxygen sensor aging tips
  17. Standard oxygen concentration input
  18. Diameter of combustion cylinder can be set (two common specifications are optional)
  19. Flow regulation range: 0-20l /min (0-1200l /h)
  20. 20.quartz glass tube: two specifications either (Durchmesser 75 ㎜ or inner diameter or greater or higher 85 mm)
  21. Gas flow rate in combustion cylinder: 40mm±2mm/s
  22. 2 Gesamtabmessungen: 650mm * 400 * 830mm
  23. Pressure gauge accuracy 2.5, Auflösung: 0.01MPA
  24. The test environment: the environment temperature: room temperature ~ 40 ℃;, relative Luftfeuchtigkeit: 70%;
  25. Input pressure: 0.25-0.3MPA
  26. Working pressure: nitrogen 0.15-0.20mpa oxygen 0.15-0.20mpa
  27. The specimen holder can be used for soft and hard plastics, various building materials, textiles, fire doors, usw
  28. Propane (butane) ignition system, the ignition nozzle is made of a metal, the end has Φ 2±1mminner diameter nozzle, can be bent freely.Can be inserted into the combustion tube to ignite the sample, the flame length: 16 4mm, the size of 5mm-60mm can be adjusted freely,
  29. Gas: nitrogen and oxygen for industrial use with purity of > 99%;(the purity of industrial oxygen in user-provided/normal gas stations is generally between 99.2% Und 99.3%).
  30. Power requirements: AC220 (+10%) V, 50HZ
  31. Maximum power: 150W
  32. Self-supporting material sample holder: it can be fixed in the position of the axis of combustion cylinder and can hold the sample vertically
  33. Non-self-supporting material sample holder: it can fix two vertical edges of the sample on the frame at the same time (optional/applicable to soft non-self-supporting materials such as textiles).

Tips: when testing oxygen index tester, one bottle of industrial-grade oxygen/nitrogen of no less than 98% should be used as gas source. As the above gas is high-risk transport, it cannot be used as accessories of oxygen index tester, so it can only be purchased from local gas stations of users.(in order to ensure the purity of the gas, please purchase it at a local regular gas station)