Beschreibung

GA-2801 Air Tightness Leak Detector

Verwenden

GA-2801 series air tightness detector adopts the principle of direct pressure and uses air as the medium to pick up the leakage of the product. It is a non-destructive testing instrument.The working principle is to inflate the test product to the specified air pressure, then close the valve, after a period of stability, measure the change of air pressure during the test period, calculate the leakage through conversion.With its high precision and complete function, this instrument is widely used in sealing testing of open products or parts of closed products.

 

GA-2801 Air Tightness Leak Detector

Funktionsmerkmale

  • 7 inch touch screen display, Chinese and English language switch.
  • Large leakage, small leakage 2 alarm functions.
  • Alarm set,self-setting,Leakage pressure cap,Test pressure lower limit
  • Usb disk history storage, query, print, delete, Bildschirmfoto
  • Datenspeicher,the instrument can store test results 24 hours a day
  • Test time can be set for each stage (0.1s-999s)
  • External control, do not need to use PLC program to achieve cylinder control

 

GA-2801 Air Tightness Leak Detector

Anwendungsfelder

Widely used in: electronic consumer goods, can only wear, wire material, Automobil, motorcycle industry, battery industry, valve pipe fittings, connection pipe, solenoid valve, lamps and lanterns, fire equipment, military supplies, household appliances and other fields

 

GA-2801 Air Tightness Leak Detector

Technische Spezifikation

Modell GA-2801LF

Negative pressure Low pressure

GA-2801MF

Negative pressure Middle pressure

 

GA-2801F

Negative pressure

GA-2801L

Low pressure

GA-2801M

Middle pressure

GA-2801H

High pressure

Auflösung 1pa 5pa 1pa 1pa 5pa 20pa
Positive pressure test 1~130kpa 5~700kpa NEIN 1~130kpa 5~700kpa 0.2~2Mpa
Negative pressure test -85~-1kpa -85~-1kpa -85~-1kpa NO NO NO
I/O Interface 7 input signals / 7 output signals
Test volume The test product volume is less than 10 liters, the smaller the volume, the faster the test speed.
Historical data Historical data records show
Testzeit Prepare1–prepare 2–pressurized–balance–detection–Auspuff–entfernen

Reichweite:0.1s~~999.0s

Größe D310*W310*H210(mm)
Gewicht About 8KG
Leistung AC 220V±10%,50/60HZ,Consumption of electricity:50VA
Test pressure source Dry clean air source with high flow and stable pressure
Ambient temperature and humidity Use of temperature:5~40℃,storage temperature -20℃~70℃,below 80%RH,

But no condensation