ASTM D1200-2018 Test Method for Viscosity Determination with Ford Viscosity Cup

ASTM D1200-2018 Test Method for Viscosity Determination with Ford Viscosity Cup

Bedeutung und Zweck
5.1 The test method can be used to determine the packaging and application viscosity of many paints and other coatings and the dilution of these materials, but is limited to Newtonian or near-Newtonian liquids.

5.2 There are other types of equipment used to measure viscosity in the laboratory that can produce more accurate results.

Geltungsbereich
1.1 The test method consists of the determination of the viscosity of Newton or near-Newton paints, Lacke, varnishes and related liquid materials using a Ford-type external discharge viscosity cup. If the material is non-Newtonian, das ist, shear thinning or thixotropic, test method D2196 should be used.

Test Method for Viscosity Determination with Ford Viscosity Cup

1.2 In SI-Einheiten ausgedrückte Werte gelten als Standards. Die in Klammern angegebenen Werte dienen nur als Referenz.

1.3 Diese Norm soll nicht alle Sicherheitsprobleme behandeln, wenn überhaupt, mit seiner Verwendung verbunden. Es liegt in der Verantwortung des Anwenders dieser Norm, für angemessene Sicherheit zu sorgen, Gesundheits- und Umweltpraktiken zu prüfen und vor der Verwendung die Anwendbarkeit behördlicher Beschränkungen zu ermitteln.

1.4 Dieser internationale Standard wurde in Übereinstimmung mit den international anerkannten Standardisierungsgrundsätzen entwickelt, die in der Entscheidung über Grundsätze für die Entwicklung internationaler Standards festgelegt sind, Richtlinien und Empfehlungen des Ausschusses für technische Handelshemmnisse der Welthandelsorganisation.