CH8710B Battery Discharge Electronic Load
- Popis
- Poptávka
Popis
CH8710B Battery Discharge Electronic Load
Představení produktu:
The economic program-controlled DC electronic load series can measure up to 360V, which can be widely used in non isolated LED driving power supply, power transformer, nabíječka, switching power supply, battery and other industries, such as online testing and laboratory testing fields.
The display of the instrument is intuitive, comprehensive and easy to operate. Its perfect functions of constant voltage, constant current, constant power, constant resistance, remote measurement, short circuit test, battery test, dynamic test and upper computer software control enable you to obtain the multi-purpose benefits and convenience of one computer.
CH8710B Battery Discharge Electronic Load
Hlavní rysy:
■ Maximum 360V test voltage to meet the test requirements of non-isolated driving power supply
■ Fixed Current, Fixed Voltage, Fixed Resistance, Fixed Power Mode
■ Dynamic measurement mode
■ Battery Testing Mode
■ List Automated Test Mode
■ Standard RS232C interface
■ Remote Testing Function
■ Over Voltage, Over Current, Over Power, Over Temperature Protection
CH8710B Battery Discharge Electronic Load
Major Technical Indicators:
| Modelka | CH8710B | CH8710C | CH9710B | CH9710C | |
| Rated value | Vstupní napětí | 0~360V | |||
| Vstupní proud | 1mA~30A | 0.1mA~30A | |||
| Input power | 150W | 300W | 150W | 300W | |
| Režim zobrazení | LED with backlight | High brightness VFD | |||
| Rozsah | Přesnost | Resolving Power | Přesnost | Resolving Power | |
| Load accuracy | 0-36PROTI | ±(0.1%+0.03%FS) | 1mV | ±(0.05%+0.03%FS) | 1mV |
| 0-360PROTI | ±(0.1%+0.03%FS) | 10mV | ±(0.05%+0.03%FS) | 10mV | |
| 0-3A | ±(0.1%+0.1%FS) | 1mA | ±(0.05%+0.05%FS) | 0.1mA | |
| 0-30A | ±(0.2%+0.3%FS) | 10mA | ±(0.05%+0.05%FS) | 1mA | |
| Fixed Voltage Mode | 1.5V-36V | ±(0.1%+0.03%FS) | 1mV | ±(0.05%+0.03%FS) | 1mV |
| 1.5V-360V | ±(0.1%+0.03%FS) | 10mV | ±(0.05%+0.03%FS) | 10mV | |
| Fixed Current mode | 0-3A | ±(0.1%+0.1%FS) | 1mA | ±(0.05%+0.03%FS) | 0.1mA |
| 0-30A | ±(0.2%+0.3%FS) | 10mA | ±(0.05%+0.03%FS) | 1mA | |
| Fixed Resistance mode | 0.1Ω-10Ω | ±(1%+0.3%FS) | 0.001Ach | ±(0.2%+0.2%FS) | 0.001Ach |
| 10Ω-99Ω | ±(1%+0.3%FS) | 0.01Ach | ±(0.1%+0.1%FS) | 0.01Ach | |
| 100Ω-999Ω | ±(1%+0.3%FS) | 0.1Ach | ±(0.1%+0.1%FS) | 0.1Ach | |
| 1KΩ-4KΩ | ±(1%+0.8%FS) | 1Ach | ±(1%+1%FS) | 1Ach | |
| Fixed Power mode | 0-10W | ±(1%+0.1%FS) | 1mW | ±(0.1%+0.1%FS) | 1mW |
| 10-100W | ±(1%+0.1%FS) | 10mW | ±(0.1%+0.1%FS) | 1 0mW | |
| 100-300W | ±(1%+0.1%FS) | 0.1 W | ±(0.1%+0.1%FS) | 0.1 W | |
| Current measurements | 0-3A | ±(0.1%+0.1%FS) | 1mA | ±(0.05%+0.05%FS) | 0.1mA |
| 0-15A/30A | ±(0.2%+0.3%FS) | 10mA | ±(0.05%+0.05%FS) | 1mA | |
| Voltage measurements | 1.5V-36V | ±(0.1%+0.03%FS) | 1mV | ±(0.05%+0.03%FS) | 0.1mV |
| 1.5V-360V | ±(0.1%+0.03%FS) | 10mV | ±(0.05%+0.03%FS) | 1mV | |
| Battery Test Function | Vstupní napětí:0.8-360PROTI Maximum capacity:999A/H Resolving Power:10mA Discharge time:1~60000sec |
Vstupní napětí:0.8-360PROTI Maximum capacity:999A/H Resolving Power:0.1mA Discharge time:1~60000sec |
|||
| Dynamic Test mode | T1&T2(A or B Value Test Time): 1mS-999S Error<3% + 1slečna |
T1&T2(A or B Value Test Time): 0.1mS-999S Error<2.5% + 0.1slečna |
|||
| Protection scope | >Rated condition 5% | ||||
| Input impedance | ≥200KΩ | ||||
| Outline size | W*H*D 225mm*100mm*330mm | W*H*D 215mm*88mm*335mm | |||
| Hmotnost | About 5.5Kg | About 6.5Kg | About 5.5Kg | About 6.5Kg | |