BZY100/200 Automatic Interfacial Tensiometer
- وصف
- سؤال
وصف
BZY100/200 Automatic Interfacial Tensiometer
ملخص
High performance weight sensing based on the principle of electromagnetic force balance
Accurate measurement and good repeatability.
Both the platinum plate method and the platinum ring method are used.
Automatic measurement, one key value.
Range correction, accuracy correction function to ensure the length of the instrument
Period of accurate measurement.
Save the data and print it directly.
Interchange of Chinese and English
سمات:
*BZY100 and BZY200 are the upgraded products of BZY-101, BZY-102, BZY-201, BZY-202, إلخ., which are greatly improved in performance.
* 4.3-inch touch screen, all operations and information are completed or displayed on the screen;
* The electromagnetic force balance principle of the sensor, حساسية عالية, high precision, high repetition;
* Platinum plate method, platinum ring method;
* Automatic measurement, no calculation, directly display the surface tension value or interfacial tension value;
* One key clear zero, one key correction; Digital processing technology, no deviation;
* Users can calibrate data with standard samples (distilled water and pure ethanol) to ensure measurement accuracy;
* Display measurement curve in real time, save measurement results, print main parameters, data and curves;
* Double door transparent plexiglass wind hood, سهل تنفيذه, reduce the use of environmental requirements;
* Password management function to ensure data traceability, prevent data modification and mis-deletion;
* Chinese/English interchange operation
المعايير
ASTM D971 , ASTM D1331 ,ASTM D1417 ,الخاص بك 14210 ,الخاص بك 14370 ,ايزو 304 ,ايزو 1409 .ISO 4311,ISO 6889
BZY100/200 Automatic Interfacial Tensiometer
طلب field
1) Oil aging test, especially transformer oil (ASTM D-971)
2) Determination of Surfactant Effectiveness in Wetting Agents and Cleaners Test Surfactant Solution Concentration.
3) Canning approval and cleaning validation in the food industry.
4) Interfacial tension measurements for quality control and optimization of emulsifiers.
5) Cooling lubricant surface tension test.
BZY100/200 Automatic Interfacial Tensiometer
Product تحديد
| نموذج | BZY100 | BZY200 |
| Test Method* | Du Nouy Ring Method & Wilhelmy Plate Method | |
| Test Range | 0-1000ملي نيوتن / م | 0-1000ملي نيوتن / م |
| دقة | 0.1ملي نيوتن / م | 0.01ملي نيوتن / م |
| Operation Method | Automatic lifting and lowering of sample stage Automatic measurement | |
| Display Method | 4.3-inch touch screen data direct reading | |
| Data Method | Support data storage/view/print | |
| Measure Time | Normally within 60 ثواني | |
| Data Output** | RS232 (Printer) | |
| أبعاد | 28*20*36سم(الطول*العرض*الارتفاع) | |
| الوزن الصافي | 8كلغ | |
| مزود الطاقة | 110V or 220V ,30دبليو | |