GA-9020 Mask Flame Retardant Tester
- Beskrywing
- Ondersoek
Beskrywing
GA-9020 Mask Flame Retardant Tester
Testing standard:
Medical surgical mask
The flame retardant tester of surgical mask produced by our company is used for the flame retardant tester of surgical mask.Medical surgical mask meets the test standard yy0469-2011 EN149.
Equipment features
- Automatic ignition.
- Digital display of flame temperature.
- Automatic movement for detection.
GA-9020 Mask Flame Retardant Tester
Technical parameters of detector
- Flame tempe
- rature: 800±50℃.
- The movement speed of the head mold is 60±5mm/s.
- The flame height is 40±4mm.
- The distance between the combustion top and the bottom of the sample is 20±2mm
Parameter
| Product name | Mask flame retardant tester | |
| Basic principle | The combustion test was carried out by adjusting the propane unit | |
| flame temperature | 800±50℃ | |
| Time accuracy | 0.1s | |
| test medium | dimethylmethane | |
| control mode | utomatic control | |
| Omvang van toepassing | Surgical masks | |