Ozone Climatic Chamber
Ttegnies Pafmetings:
| 1.Product Name | Ozone Climatic Chamber |
| 2.Model | GA-2013-B |
| 3.Limit sample | The test equipment is prohibited:
(1) Toets of berging van monsters van ontvlambare, explosive and volatile substances (2) Test or storage of corrosive substances (3) Testing or storage of biological samples (4).The test or storage of strong electromagnetic emission source samples
|
| Ozone Climatic Chamber
4.Volume, Dimensie , Gewig |
|
| 4.1.Nominal content product | 150L |
| 4.2.The type size | W500*H600*D500mm |
| 4.3.External dimension | W950*H1750*D1000mm |
| 4.4.Gewig
|
About 250KG |
| Ozone Climatic Chamber
5.Pprestasie |
|
|
5.1Test Environmental Conditions
5.2.Test Method |
The ambient temperature is +25℃, relative humidity ≤85% and there is no sample in the test chamber
* The stainless steel test chamber meets the international standard and the completely closed gas loop for producing ozone by silent discharge. The entire ozone gas generation and capture is a closed loop to ensure personal safety. * arbitrarily set ozone concentration in the range of 1000pphm. * Sample holder device driven by speed regulating motor (It satisfies the static tensile test, and the specimen’s running trajectory satisfies the cycloidal trajectory principle) * Ozone concentration automatic digital display control instrument. * Double beam “QUA” non-dispersive ultraviolet ozone detector. * Digital display automatic online measurement. * There is a calibration interface for metrological verification. * Ozone concentration/temperature and humidity setting value control PID self-setting, convenient and reliable operation. * 3rd generation Bill Lambert measurement application software. * Security door lock control system
|
| 5.3.Ozone concentration range | 20~500 pphm(Set up direct reading) |
| 5.4.Ozone concentration deviation | Ozone concentration deviation: nasionale standaard 10% |
| 5.5.Test chamber temperature | Measurement range: room temperature ~ +70℃ (temperature range when ozone occurs) |
| 5.6.Relatiewe humiditeit |
Measurement range below 60%RH (humidity range when ozone occurs)
|
| 5.7.Specimen holder | 360 degree rotating sample stand (static) |
| 5.8.Dynamic stretching | Each fixture can install test pieces of tensile type can meet Ⅰ dumbbell dynamic work piece and the actual workpiece |
| 5.9.Test gas flow rate | 0-60L/min |
| 5.10.Temperatuurspeling | 0℃→+100℃(Arbitrary setting) |
| 5.11.Humiditeitsreeks | 20-65%RH |
| 5.12.Temperatuur fluktuasie | ±0.5℃ |
| 5.13.Humidity fluctuation | ±2,5% |
| 5.14.Temperature Departure | ±2.0℃ |
| 5.15.Humidity Deviation | ±3.0%RH |
| 5.16.Condition of Loading | Not have |
| 5.17.Working noise | A levels of 70 db (A) of minder
(Measured in a sound-proof room with ambient temperature of 25℃ and little echo;A was used to calculate weight and test the average value of 8 points.Each test point is 1 m horizontally away from the noise source and 1 m above the ground.) |
| 5.18.Meet test standard | Equipment used for testing ozone aging performance of rubber and its products:JIS K 6259 ASTM1149 ISO1431 GB/T7762 GB/T13642 |
Ozone Climatic Chamber
6.Architectural Feature:
6.1.Insulation enclosure:(1) Outer wall material: A3 steel plate with electrostatic spraying
(2).Binnemuur materiaal: mirror stainless steel plate SUS# 304.
(3).Box isolasie materiaal: 100mm high temperature resistant rigid polyurethane foam.
(4).Insulation material for box door: 100mm high temperature resistant rigid polyurethane foam.
6.2.Bottom structural strength:The heavy capacity of track at the bottom of the test box: ≤100Kg/m (laai). The bottom plate of the studio is welded with 4mm channel steel.
6.3. Air conditioning passage Stainless steel long axis centrifugal fan: 1 /90W.
Fan, heater, verdamper (and dehumidifier), drainage device, pressure balance port, adjustable air guide plate, Temperatuur sensor
6.4.(1).Standard configuration of test box Window 250x350x40mm 3 layers of vacuum toughened glass.
(2).Flush type handle,
(3).Deurskarnier :HULLE #304 inlet hinge
(4).Energy-saving light in the box: LED light emitting way
(5).Lead hole: 50mm 1 (with a rubber plug)
(6).Ozone discharge outlet: 50mm towards outdoor